Alcatel omc software download




※ Download: Alcatel omc software download





OXO Connect is a new generation of robust, connected and converged communication platforms, entirely dedicated to small and medium businesses.

Alcatel omc software download

TERMINAL GROUP Series of terminals grouped under the same directory number. In a Hotel installation, all the Z terminals are used as hotel room terminals except the first which is a fax and the second which is a public telephone.

Alcatel omc software download

If a software key is not present in the system, or is incorrect, the system starts in a limited state. It will be requested during the generic SIP set configuration... Omnipcx Management Console Download Minecraft Omnipcx office management console Free Download for Windows Child.


All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Chapter 2 Hardware: Platform and Interfaces Overview.................... OmniPCX Office RCE Compact.............. OmniPCX Office RCE Small................

OmniPCX Office RCE Medium.............. OmniPCX Office RCE Large................. Chapter 3 System Services Software Licence Management............ Chapter 8 Glossary Glossary.................... In order to better serve its customers, Alcatel-Lucent Enterprise reserves the right to modify the characteristics of its products without notice. Alcatel-Lucent Enterprise - 32, avenue Kléber F-92707 Colombes Cedex RCS Paris 602 033 185.

Installation of the mains power The mains power must be installed as close as possible to the unit and must be easily accessible. The Mini-MIX daughter board can be used only in an OmniPCX Office RCE Compact or, in case of migration from R7. Japan - VCCI Voluntary Control Council for Interference Translation : This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI.

If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. The stations are packaged separately. Platforms Alcatel-Lucent OmniPCX Office Communication Server is available in the following models: 2.

The Mini-MIX daughter board, plugged on a PowerCPU booard, requires an OmniPCX Office RCE Compact, or, in case of migration from Release 7. The Mini-MIX daughter board cannot be used on an Alcatel-Lucent OmniPCX Office Compact Edition. Board Function Optional boards Connections... The UAI16-1 board is used to power terminals connected to the 16 interfaces remotely from an EPS48 external power supply connected to interface 1 via an external adapter cable splitter.

Caution: Only use EPS48 power supplies and the splitters provided. Daughter Boards OmniPCX Office RCE Compact OmniPCX Office RCE Small, Medium, Large ARMADA VoIP32... MSL MAIN key or. CSL CTI key extension. If a software key is not present in the system, or is incorrect, the system starts in a limited state.

The table also gives the limited state service levels, the granularity of upgrades, the maximum service level for each service, and if a hardware extension exists. In default state reached after 30 days of temporary state, the license 2B channels on mixed board is set to 24. Then, if there is a SWL upgrade, which permits 4 ports and automated attendant, you will need to create two new ports, present in the attendant default group and in the first hunting group.

Output data will be provided in a simple XML format interface. This license must be opened for OHL needs. In OMC, the creation of a new My IC Mobile for iPhone subscriber or a new My IC Mobile for Android subscriber is refused if the total number of existing such subscribers has reached the maximum value indicated by the present license item.

In both cases, use the hole drilling template supplied with the platform. If mounting the Alcatel-Lucent OmniPCX Office Communication Server platform results in exceeding the load on the front supports generally the total weight divided by two , the... Ensure that no objects are placed on the upper part of the system to restrict the extraction of hot air.

Each terminal is connected up by a pair of 0. System - digital terminal distances: 0. All the box connections are made with straight RJ45-RJ45 cables. Output connector functions: BRA: connection of T0 access to be forwarded. NT: connection of ISDN network termination. S0: connection of forwarding S0 station. Remark: We recommend using an L120-series cable or the L204 equivalent.

It is connected via the ALARM output control contact closed when idle of the AUDIO connector. NPTT Type B: doorphones controlled by MF Q23 signals requiring an SLI interface e.

TELEMINI and UNIVERSAL DOORPHONE The doorphone interface comprises an intercom and an optional latch powered by the mains supply through a SELV Safety Extra Low Voltage transformer. The system also allows for the connection of 2 doorphones without latch. Connecting a Telemini and Universal Doorphone These doorphones require the use of a Z station interface. Several of these doorphones can be connected to the system;... It has the following characteristics: OmniPCX Office RCE Small and OmniPCX Office RCE Large: 6.

The connection procedure is the same for OmniPCX Office RCE Medium and OmniPCX Office RCE Large platforms, but is different for OmniPCX Office RCE Small platforms.

It uses 12V - 7Ah batteries. Either one battery or three batteries can be installed in the unit. Open the unit by removing the four screws ST3. Insert the batteries in the open unit as follows also see the figure below : a. It uses three 12V - 7Ah batteries. Two external battery units can be connected in parallel to obtain the autonomy achieved with six batteries.

Open the unit by removing the four screws ST3. Installation of External Batteries for the OmniPCX Office RCE Medium and OmniPCX Office RCE Large Platforms...

Stop the Alcatel-Lucent OmniPCX Office Communication Server system, and remove the power supply cord from the platform side. Disconnect the power supply cable on the platform side before handling the power supply.

This operation disconnects the mains supply and the internal battery. Ensure that the J1 jack is NOT connected to the OmniPCX Office RCE Compact platform. Insert the batteries in the open unit as follows see the figure below : a. Place the first battery in the middle position battery B1. If a second battery is to be used, place this battery in the remaining position battery B2. Using a screwdriver, unscrew the power supply module PSXS or PSXS-N from the side of the OmniPCX Office RCE Compact platform and pull the module out of the cabinet.

It is mandatory to use a power supply module PSXS-N with reference 3EH73072ACxx on an OmniPCX Office RCE Compact platform equipped with a PowerCPU board and a hard disk. UPS Connection - module: use the cable supplied with the UPS For an installation using 3 Alcatel-Lucent OmniPCX Office Communication Server modules, 2 UPSs are required: one feeds two of the modules, the other feeds the third module.

It is connected via a jack plug at the front of the module right hand side. Configure the user name and password in OMC, refer to Configuring the user name and password in OMC Prerequisites The Alcatel-Lucent OmniPCX Office Communication Server version must be R9. This operation is not mandatory. In the DHCP offer, the data within Option 43 corresponds to the client vendor ID specified in the request.

The DHCP offer provides the following parameters: 4-36... Configuring the DHCP server for dynamic initialization... Enter the IP Address of the OmniPCX Office , click Next 3. The configuration wizard will connect to the OmniPCX Office. If unsuccessful, the invitation to enter the correct IP Address for the OmniPCX Office is presented. Select the line to control and enter the voice mailbox password for that line extension, click Next 5.

You can click on Export to produce a file that can be renamed and saved on your disk. The file contains diagnostic information that can be provided to the Technical Support.

The number displayed next to the My IC Social Networks contact, is the actual number My IC Social Networks will dial. For your specific installation, please check with your OmniPCX Office system installer. Their default functions depend on:... However, in this case the virtual keys are selected using 4 physical buttons, 2 on each side of the set's display, as shown below.

The procedures below show the Alcatel-Lucent IP Touch 4068 Phone interface, but the menus are the same using the Alcatel-Lucent IP Touch 4038 Phone or Alcatel-Lucent 4039 Digital Phone interface and are similar using the Advanced interface. To restart the session if you quit using the Exit function 6. The number of your installation can include a maximum of three fields for a total of 18 digits. Any modification of the numbering plan causes the deletion of any existing DDI numbers.

In a Hotel installation, all the Z terminals are used as hotel room terminals except the first which is a fax and the second which is a public telephone. A pool of DDI numbers means that these terminals can be assigned with a dynamic DDI number when a customer checks in.

It contains 11 octal digits base 8. This number, assigned to an ETSI base by the installer, must be entered on installing the system. The cost not the duration and the changes in the charge meters during calls are displayed. The value entered can contain 5 figures 0-2 decimal places in the chosen monetary unit. In this case the network connection is not necessary. This access can be managed using: an ISDN modem able to use ISDN PPP point to point protocol at 64K 1 B-channel or...

This modem provides a point-to-point communication link accessible via standard LINUX protocols PPP, etc. For each layer, Alcatel-Lucent OmniPCX Office Communication Server carries out an access control. To connect a remote OmniPCX Office via a proxy server, the login dialog box can request a user account and password to connect to the proxy server.

The first thing an attacker will do is rummage through your personal belongings. Any power shut down during the BIOS downloading will damage the PowerCPU. Mode 1: Data and tool repository 2.

Mode 2: Typical installation 3. Mode 3: Typical modification 4. Mode 4: Expert 5. Mode 5: Multisite Important: Access to modes 2, 3, 4 and 5 is password protected: pbxk1064 using the OMC tool Access to modes 2 and 3 is password protected: help1954 using the OMC Easy tool 6. It allows you to manage several Alcatel-Lucent OmniPCX Office Communication Server systems.

The Multisite feature includes the following basic services: An Installation Wizard to help installers and administrators to set up appropriate configurations when adding PBXs to a network.

Dead batteries must be disposed of according to the battery manufacturer's instructions. It is also forbidden for PowerCPU boards in all platforms. If a hot installation is not possible, stop the system and disconnect it from the mains power...

It is also forbidden for PowerCPU boards in all systems. If a hot swap is not possible, stop the system and disconnect it from the mains power supply.

Avoid any knocks to the hard disk Do not touch the connector Handle the disk by holding it by the sides 7. A computerized phone system that responds to the caller with a voice menu, and connects the call to the required agent. It can also control call flows by automatically routing calls in the order of arrival. ACSE Association Control Service Element. Control protocol associated with BAP. PPP protocol that manages bandwidth by allocating it dynamically between two ports, i.

Service that allocates bandwidth automatically in response to traffic volume. Direct external call number for the system terminals depending on the configuration with the public network operator.

DECT Digital Enhanced Cordless Telecommunication. European cordless telephony standard. DECT terminal: cordless terminal that complies with this standard. Workstation allowing a communication server administrator to remotely manage, administer storage of call metering tickets for example and optimize one or more Alcatel-Lucent OmniPCX Office Communication Server systems.

Remote access server to the system LAN. Rich Communication Edition for example, OmniPCX Office RCE Compact is the short designation for Alcatel-Lucent OmniPCX Office Rich Communication Edition Compact. Resource key for a particular destination; supports local calls for this number if assigned to a speed dial number, incoming calls for the number if assigned to a DDI number, or outgoing calls on a trunk group if assigned to a trunk group.

TERMINAL GROUP Series of terminals grouped under the same directory number. Any call to that number is routed to a free terminal line. TFTP Trivial File Transfer Protocol. The simplest network application for transferring files. Analog Trunk Line connecting the system to the public switched network.

WLAN handsets are sometimes referred to as MIPT Mobile IP Touch handsets.


Alcatel omc software download

Alcatel Lucent Omc Freeware - Alcatel omc software download


Alcatel omc software download
While using the basic Windows screenshot capture method is available, it is not adequate for everyone. Chapter 8 Glossary Glossary. In a Hotel installation, all the Z terminals are used as hotel room terminals except the first which is a fax and the second which is a public telephone. Mode 1: Data and tool repository 2. Hyper- V Management Console allows organizing virtual machines in lists. If a software key is not present in the system, or is incorrect, the system starts in a limited state.
Alcatel omc software download
Alcatel 4018 IP Phone IP Configuration
Alcatel omc software download

All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Chapter 2 Hardware: Platform and Interfaces Overview.................... OmniPCX Office RCE Compact.............. OmniPCX Office RCE Small................

OmniPCX Office RCE Medium.............. OmniPCX Office RCE Large................. Chapter 3 System Services Software Licence Management............ Chapter 8 Glossary Glossary.................... In order to better serve its customers, Alcatel-Lucent Enterprise reserves the right to modify the characteristics of its products without notice. Alcatel-Lucent Enterprise - 32, avenue Kléber F-92707 Colombes Cedex RCS Paris 602 033 185.

Installation of the mains power The mains power must be installed as close as possible to the unit and must be easily accessible. The Mini-MIX daughter board can be used only in an OmniPCX Office RCE Compact or, in case of migration from R7. Japan - VCCI Voluntary Control Council for Interference Translation : This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment VCCI.

If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. The stations are packaged separately. Platforms Alcatel-Lucent OmniPCX Office Communication Server is available in the following models: 2. The Mini-MIX daughter board, plugged on a PowerCPU booard, requires an OmniPCX Office RCE Compact, or, in case of migration from Release 7.

The Mini-MIX daughter board cannot be used on an Alcatel-Lucent OmniPCX Office Compact Edition. Board Function Optional boards Connections... The UAI16-1 board is used to power terminals connected to the 16 interfaces remotely from an EPS48 external power supply connected to interface 1 via an external adapter cable splitter. Caution: Only use EPS48 power supplies and the splitters provided.

Daughter Boards OmniPCX Office RCE Compact OmniPCX Office RCE Small, Medium, Large ARMADA VoIP32... MSL MAIN key or. CSL CTI key extension. If a software key is not present in the system, or is incorrect, the system starts in a limited state. The table also gives the limited state service levels, the granularity of upgrades, the maximum service level for each service, and if a hardware extension exists. In default state reached after 30 days of temporary state, the license 2B channels on mixed board is set to 24.

Then, if there is a SWL upgrade, which permits 4 ports and automated attendant, you will need to create two new ports, present in the attendant default group and in the first hunting group. Output data will be provided in a simple XML format interface. This license must be opened for OHL needs. In OMC, the creation of a new My IC Mobile for iPhone subscriber or a new My IC Mobile for Android subscriber is refused if the total number of existing such subscribers has reached the maximum value indicated by the present license item.

In both cases, use the hole drilling template supplied with the platform. If mounting the Alcatel-Lucent OmniPCX Office Communication Server platform results in exceeding the load on the front supports generally the total weight divided by two , the...

Ensure that no objects are placed on the upper part of the system to restrict the extraction of hot air. Each terminal is connected up by a pair of 0. System - digital terminal distances: 0.

All the box connections are made with straight RJ45-RJ45 cables. Output connector functions: BRA: connection of T0 access to be forwarded. NT: connection of ISDN network termination. S0: connection of forwarding S0 station. Remark: We recommend using an L120-series cable or the L204 equivalent. It is connected via the ALARM output control contact closed when idle of the AUDIO connector.

NPTT Type B: doorphones controlled by MF Q23 signals requiring an SLI interface e. TELEMINI and UNIVERSAL DOORPHONE The doorphone interface comprises an intercom and an optional latch powered by the mains supply through a SELV Safety Extra Low Voltage transformer.

The system also allows for the connection of 2 doorphones without latch. Connecting a Telemini and Universal Doorphone These doorphones require the use of a Z station interface. Several of these doorphones can be connected to the system;... It has the following characteristics: OmniPCX Office RCE Small and OmniPCX Office RCE Large: 6. The connection procedure is the same for OmniPCX Office RCE Medium and OmniPCX Office RCE Large platforms, but is different for OmniPCX Office RCE Small platforms.

It uses 12V - 7Ah batteries. Either one battery or three batteries can be installed in the unit. Open the unit by removing the four screws ST3. Insert the batteries in the open unit as follows also see the figure below : a. It uses three 12V - 7Ah batteries. Two external battery units can be connected in parallel to obtain the autonomy achieved with six batteries. Open the unit by removing the four screws ST3.

Installation of External Batteries for the OmniPCX Office RCE Medium and OmniPCX Office RCE Large Platforms...

Stop the Alcatel-Lucent OmniPCX Office Communication Server system, and remove the power supply cord from the platform side. Disconnect the power supply cable on the platform side before handling the power supply. This operation disconnects the mains supply and the internal battery.

Ensure that the J1 jack is NOT connected to the OmniPCX Office RCE Compact platform. Insert the batteries in the open unit as follows see the figure below : a. Place the first battery in the middle position battery B1. If a second battery is to be used, place this battery in the remaining position battery B2. Using a screwdriver, unscrew the power supply module PSXS or PSXS-N from the side of the OmniPCX Office RCE Compact platform and pull the module out of the cabinet.

It is mandatory to use a power supply module PSXS-N with reference 3EH73072ACxx on an OmniPCX Office RCE Compact platform equipped with a PowerCPU board and a hard disk. UPS Connection - module: use the cable supplied with the UPS For an installation using 3 Alcatel-Lucent OmniPCX Office Communication Server modules, 2 UPSs are required: one feeds two of the modules, the other feeds the third module. It is connected via a jack plug at the front of the module right hand side.

Configure the user name and password in OMC, refer to Configuring the user name and password in OMC Prerequisites The Alcatel-Lucent OmniPCX Office Communication Server version must be R9.

This operation is not mandatory. In the DHCP offer, the data within Option 43 corresponds to the client vendor ID specified in the request. The DHCP offer provides the following parameters: 4-36... Configuring the DHCP server for dynamic initialization... Enter the IP Address of the OmniPCX Office , click Next 3. The configuration wizard will connect to the OmniPCX Office. If unsuccessful, the invitation to enter the correct IP Address for the OmniPCX Office is presented. Select the line to control and enter the voice mailbox password for that line extension, click Next 5.

You can click on Export to produce a file that can be renamed and saved on your disk. The file contains diagnostic information that can be provided to the Technical Support. The number displayed next to the My IC Social Networks contact, is the actual number My IC Social Networks will dial. For your specific installation, please check with your OmniPCX Office system installer. Their default functions depend on:... However, in this case the virtual keys are selected using 4 physical buttons, 2 on each side of the set's display, as shown below.

The procedures below show the Alcatel-Lucent IP Touch 4068 Phone interface, but the menus are the same using the Alcatel-Lucent IP Touch 4038 Phone or Alcatel-Lucent 4039 Digital Phone interface and are similar using the Advanced interface.

To restart the session if you quit using the Exit function 6. The number of your installation can include a maximum of three fields for a total of 18 digits. Any modification of the numbering plan causes the deletion of any existing DDI numbers. In a Hotel installation, all the Z terminals are used as hotel room terminals except the first which is a fax and the second which is a public telephone.

A pool of DDI numbers means that these terminals can be assigned with a dynamic DDI number when a customer checks in. It contains 11 octal digits base 8. This number, assigned to an ETSI base by the installer, must be entered on installing the system.

The cost not the duration and the changes in the charge meters during calls are displayed. The value entered can contain 5 figures 0-2 decimal places in the chosen monetary unit. In this case the network connection is not necessary.

This access can be managed using: an ISDN modem able to use ISDN PPP point to point protocol at 64K 1 B-channel or... This modem provides a point-to-point communication link accessible via standard LINUX protocols PPP, etc.

For each layer, Alcatel-Lucent OmniPCX Office Communication Server carries out an access control. To connect a remote OmniPCX Office via a proxy server, the login dialog box can request a user account and password to connect to the proxy server.

The first thing an attacker will do is rummage through your personal belongings. Any power shut down during the BIOS downloading will damage the PowerCPU. Mode 1: Data and tool repository 2. Mode 2: Typical installation 3.

Mode 3: Typical modification 4. Mode 4: Expert 5. Mode 5: Multisite Important: Access to modes 2, 3, 4 and 5 is password protected: pbxk1064 using the OMC tool Access to modes 2 and 3 is password protected: help1954 using the OMC Easy tool 6. It allows you to manage several Alcatel-Lucent OmniPCX Office Communication Server systems. The Multisite feature includes the following basic services: An Installation Wizard to help installers and administrators to set up appropriate configurations when adding PBXs to a network.

Dead batteries must be disposed of according to the battery manufacturer's instructions. It is also forbidden for PowerCPU boards in all platforms. If a hot installation is not possible, stop the system and disconnect it from the mains power...

It is also forbidden for PowerCPU boards in all systems. If a hot swap is not possible, stop the system and disconnect it from the mains power supply. Avoid any knocks to the hard disk Do not touch the connector Handle the disk by holding it by the sides 7. A computerized phone system that responds to the caller with a voice menu, and connects the call to the required agent. It can also control call flows by automatically routing calls in the order of arrival.

ACSE Association Control Service Element. Control protocol associated with BAP. PPP protocol that manages bandwidth by allocating it dynamically between two ports, i. Service that allocates bandwidth automatically in response to traffic volume. Direct external call number for the system terminals depending on the configuration with the public network operator. DECT Digital Enhanced Cordless Telecommunication. European cordless telephony standard. DECT terminal: cordless terminal that complies with this standard.

Workstation allowing a communication server administrator to remotely manage, administer storage of call metering tickets for example and optimize one or more Alcatel-Lucent OmniPCX Office Communication Server systems.

Remote access server to the system LAN. Rich Communication Edition for example, OmniPCX Office RCE Compact is the short designation for Alcatel-Lucent OmniPCX Office Rich Communication Edition Compact. Resource key for a particular destination; supports local calls for this number if assigned to a speed dial number, incoming calls for the number if assigned to a DDI number, or outgoing calls on a trunk group if assigned to a trunk group.

TERMINAL GROUP Series of terminals grouped under the same directory number. Any call to that number is routed to a free terminal line. TFTP Trivial File Transfer Protocol.

The simplest network application for transferring files. Analog Trunk Line connecting the system to the public switched network. WLAN handsets are sometimes referred to as MIPT Mobile IP Touch handsets.

Categories: download